Serial Sensor Signal Conditioning
Serial signal conditioners read sensors and send the readings to a computer as digital data. Two ways: USB, when the sensors are near a PC – four channels on one cable, software included – and Modbus RS-485, when there are many points or long distances to cover on one cable to a PC or PLC.
Sensors straight to a PC
Plug the ROI-USB into a spare USB port, wire up to four sensors and start reading. The module is powered by the PC, scales each reading to engineering units, and comes with ROI viewing and recording software (Lite edition) for charts, data files and live readings in Excel.
| Version | Connects | Details |
|---|---|---|
| 10K thermistor | 4 × 10K NTC thermistors | USB thermistor recording |
| 4-20 mA | 4 × 4-20 mA transmitters (transmitter power not included) | USB 4-20 mA recording |
| 0-5 V | 4 × 0-5 V signal conditioners (conditioner power not included) | 0-5 V signal monitoring |
Example: 4-20 mA transmitters wired to a USB converter – two wires in, two wires out.
Many points on one cable
When sensors are spread out or there are more than a few, Modbus RS-485 carries them all on one cable to a PC, PLC or SCADA system. Transmitters feed ROI-IOM I/O modules, configured and tested as part of a Robert Owen system – from a few points to hundreds.
- 4-20 mA, 0-30 V and switch-contact inputs per module
- Thermistors, RTDs and potentiometers through our transmitters
- Relay outputs for alarms and control
- Modbus RTU or ASCII, our own firmware
USB or RS-485?
| USB (ROI-USB) | Modbus RS-485 (ROI-IOM) | |
|---|---|---|
| Best for | A few sensors near a PC | Many points, long distances, PLC or SCADA |
| Channels | 4 per module | 4 inputs per module, many modules per cable |
| Reads into | A Windows PC | A PC, PLC or SCADA system |
| Software | ROI viewing and recording software included | Software or PLC/SCADA setup as part of the system |
| How it’s sold | Module | Complete system |
No cable possible at all? See wireless signal conditioning.
Serial sensor signal conditioning – common questions
What is a serial sensor signal conditioner?
A device that reads sensors, converts them to scaled digital readings and sends them to a computer over a serial connection such as USB or RS-485.
Do I need software?
The ROI-USB includes ROI viewing and recording software. Modbus RS-485 systems come with software or PLC/SCADA setup as part of the system.
Does the ROI-USB need a power supply?
No – it is powered by the PC. 4-20 mA transmitters and 0-5 V signal conditioners need their own supply.
How many sensors can I read?
Four per ROI-USB. With Modbus RS-485, many ROI-IOM modules share one cable – from a few points to hundreds.
Sensors to connect to a PC or PLC?
Tell us the sensors, how many and where the readings need to go.