ROI Viewing and Recording Software – Pro Edition
See and record up to eight ROI-650 units in one window. The Pro edition is the viewing and recording software for larger systems: connect units by USB or over the network, watch every thermocouple on one channel table, charts and digital meters, record all units side by side in one file or one file per unit, and stream the readings live into Excel or DASYLab.
Standard or Pro edition
Both editions share the same screens, data file recording and live data links. The standard edition reads one unit per window. The Pro edition reads up to eight at once, keeps them on one time base and records them together.
| Feature | Standard | Pro |
|---|---|---|
| Units per window | 1 | Up to 8 |
| Connect by USB, Modbus TCP, or simulator | Included | Included, per unit |
| Channel setup: label, units, m/b scaling | Included | Included |
| Charts and digital meters | Included | Included |
| CSV data file recording | Included | Included |
| Live data to Excel and DASYLab | Included | Included |
| Automatic reconnect and recovery | Included | Included, per unit |
| Setup files | Included | Included, opens standard files |
| All units in one combined file, on one time base | — | Pro |
| One data file per unit, alongside or instead | — | Pro |
| Your own value for missing data (e.g. −9999) | — | Pro |
| Status of every unit at a glance | — | Pro |
Watching one ROI-650? The standard edition covers it. Choose Pro when several units should be watched and recorded together.
Everything on one screen,
no programming
The Pro edition shows every active channel of every unit in one table: unit, label, units, scaling and the live reading. A filter shows one unit at a time when the list gets long. Charts and digital meters open beside it.
- Units tab with U1 to U8: tick a unit to use it and pick how it connects
- Channel setup with labels, engineering units and linear scaling (m and b) per channel
- Charts with a selectable time window, up to eight stacked charts and autoscale
- Digital meters in a grid, grouped by unit, with adjustable columns and decimal places
- Data file recording to CSV with one click, from the channels you choose
- Live data into an open Excel workbook, a DASYLab worksheet or DASYLab global variables
- Setup files that save units, channels, recording and window layout, and open again on any PC
- Unit status at a glance: ready, booting, lost or off, with heartbeat, CJC temperature and reference voltage
At a glance
- Edition
- Pro – multi-unit
- Hardware
- ROI-650 precision industrial sensor I/O
- Units
- Up to 8 per window
- Channels
- 8 differential thermocouple inputs per ROI-650; up to 30 per Modbus or simulated unit
- Thermocouples
- Type J, cold-junction compensated
- Connection
- USB direct to the PC, or Modbus TCP over the network
- Views
- Channel table, charts, digital meters
- Recording
- CSV: combined file and/or one file per unit
- Live data
- Excel and DASYLab
- Platform
- Windows
Many units,
one time base
Each unit is read on its own, so a unit that is unplugged, powered down or rebooting never holds up the others. It turns red, waits for the same unit to return, restarts it and carries on.
Mix connections freely
Every unit picks its own connection. Plug ROI-650s straight into the PC by USB and pick each one by serial number. Read a unit on another machine over Modbus TCP. Or add a simulated unit to try a setup, a chart or a data file before the hardware arrives.
One poll interval for all
All units are read on the same interval. On every interval the Pro edition puts the newest reading of each unit into one row, so the combined file, Excel and DASYLab see all units side by side. A unit with no new reading gets your missing-data value instead of a stale number.
Recording built for
long, unattended runs
Test stands and surveys run for hours or days. The Pro edition keeps the record complete and easy to read back, even when a unit or a spreadsheet drops out along the way.
- Combined file with every unit side by side, columns named like “U1 CH03 (°C)”
- One file per unit, named with the unit and its serial number, alongside or instead
- Missing-data value of your choice, written wherever a reading is not available
- Date and time in the file name so every run gets its own file
- Live link reconnect: if Excel or DASYLab is busy or closed, the software retries on its own and can send the rows it missed
- CJC, reference and ID columns per unit when you want the full instrument record
Live data
- Excel
- A new row per interval, or one live row that updates in place
- DASYLab
- One line per interval into a DDE Input module
- DASYLab variables
- Each channel to a global variable
- Number format
- Decimal point or decimal comma
- Reconnect
- Retry interval of your choice
- Missed rows
- Sent on reconnect, or skipped for live use
Excel and DASYLab must run on the same PC as the software.
Example: 32-point oven survey
A temperature uniformity survey needs many thermocouples recorded on the same clock. Four ROI-650s on one PC give 32 type J points, and the Pro edition records them as one table while showing every point live.
| Unit | Connection | Measures | Goes to |
|---|---|---|---|
| U1 | ROI-650 on USB | 8 points, top shelf | Combined file, chart |
| U2 | ROI-650 on USB | 8 points, middle shelf | Combined file, chart |
| U3 | ROI-650 on USB | 8 points, bottom shelf | Combined file, chart |
| U4 | ROI-650 on USB | Air, door and load points | Combined file, digital meters |
| All units | — | One row per interval | Excel live sheet for the report |
Point locations, intervals and file layout are set up for each job. We can supply the setup file ready to run.
Where it is used
- Oven and furnace temperature surveys
- Test stands and product burn-in
- Ovens, dryers and thermal processes
- Cold storage and refrigeration
- HVAC coil and heat exchanger testing
- Laboratory temperature logging
From sensors to a data file
- Connect thermocouples to each ROI-650 and plug the units into the PC.
- Add units on the Units tab and pick each one by serial number.
- Set up channels: label, units and scaling.
- Choose recording: combined file, per-unit files, Excel or DASYLab.
- Save the setup and start recording.
Related solutions
ROI-650 precision industrial sensor I/O
24-bit, 8 differential channels and 4 digital I/O lines, DIN rail mount.
Learn more →Data acquisition software
Ready-to-run viewing, recording and Excel links – and custom software when the job needs more.
Learn more →Multi-channel distributed temperature measurement
Many sensors, ROI-IOM nodes and one RS-485 cable to a PC or PLC.
Learn more →Want the Pro edition set up for your system?
Tell us how many points you need, where they are and how you want the data recorded. We will deliver the ROI-650 units and a Pro edition setup ready to run, or the standard edition if one unit is enough.
Questions? Contact us – we look forward to answering them.