SensorVue-Pro

SensorVue-Pro · for the iNet-650

See and log up to
eight iNet-650 units
in one window

SensorVue-Pro is SensorVue for larger systems. Connect up to eight units, by USB or over the network, and watch every thermocouple on one channel table, charts and digital meters. Log all units side by side in one file, or one file per unit, and stream the readings live into Excel or DASYLab.

SensorVue-Pro showing thermocouple readings from several iNet-650 units in one channel table, with a live chart and digital meters
Choose your edition

SensorVue or SensorVue-Pro

Both editions share the same screens, logging and live data links. SensorVue reads one unit per window. SensorVue-Pro reads up to eight at once, keeps them on one time base and logs them together.

FeatureSensorVueSensorVue-Pro
Units per window1Up to 8
Connect by USB, Modbus TCP, or simulatorIncludedIncluded, per unit
Channel setup: label, units, m/b scalingIncludedIncluded
Charts and digital metersIncludedIncluded
CSV loggingIncludedIncluded
Live data to Excel and DASYLabIncludedIncluded
Automatic reconnect and recoveryIncludedIncluded, per unit
Setup filesIncludedIncluded, opens SensorVue files
All units in one combined log, on one time base—Pro
One log file per unit, alongside or instead—Pro
Your own value for missing data (e.g. −9999)—Pro
Status of every unit at a glance—Pro

Watching one iNet-650? Standard SensorVue covers it. Choose Pro when several units should be watched and logged together.

Included in both editions

Everything on one screen,
no programming

SensorVue-Pro shows every active channel of every unit in one table: unit, label, units, scaling and the live reading. A filter shows one unit at a time when the list gets long. Charts and digital meters open beside it.

  • Units tab with U1 to U8: tick a unit to use it and pick how it connects
  • Channel setup with labels, engineering units and linear scaling (m and b) per channel
  • Charts with a selectable time window, up to eight stacked charts and autoscale
  • Digital meters in a grid, grouped by unit, with adjustable columns and decimal places
  • Logging to CSV with one click, from the channels you choose
  • Live data into an open Excel workbook, a DASYLab worksheet or DASYLab global variables
  • Setup files that save units, channels, logging and window layout, and open again on any PC
  • Unit status at a glance: ready, booting, lost or off, with heartbeat, CJC temperature and reference voltage

At a glance

Edition
SensorVue-Pro (multi-unit SensorVue)
Hardware
iNet-650 Precision Industrial Sensor IO
Units
Up to 8 per window
Channels
8 differential thermocouple inputs per iNet-650; up to 30 per Modbus or simulated unit
Thermocouples
Type J, cold-junction compensated
Connection
USB direct to the PC, or Modbus TCP over the network
Views
Channel table, charts, digital meters
Logging
CSV: combined file and/or one file per unit
Live data
Excel and DASYLab
Platform
Windows
Pro feature

Many units,
one time base

Each unit is read on its own, so a unit that is unplugged, powered down or rebooting never holds up the others. It turns red, waits for the same unit to return, restarts it and carries on.

Mix connections freely

Every unit picks its own connection. Plug iNet-650s straight into the PC by USB and pick each one by serial number. Read a unit on another machine over Modbus TCP. Or add a simulated unit to try a setup, a chart or a log before the hardware arrives.

One poll interval for all

All units are read on the same interval. On every interval SensorVue-Pro puts the newest reading of each unit into one row, so the combined log, Excel and DASYLab see all units side by side. A unit with no new reading gets your missing-data value instead of a stale number.

iNet-650 USB, by serial Modbus TCP over the network Simulator no hardware SensorVue-Pro U1 – U8 one row per interval Display charts, meters CSV log combined, per unit Live data Excel, DASYLab
Pro feature

Logging built for
long, unattended runs

Test stands and surveys run for hours or days. SensorVue-Pro keeps the record complete and easy to read back, even when a unit or a spreadsheet drops out along the way.

  • Combined file with every unit side by side, columns named like “U1 CH03 (°C)”
  • One file per unit, named with the unit and its serial number, alongside or instead
  • Missing-data value of your choice, written wherever a reading is not available
  • Date and time in the file name so every run gets its own file
  • Live link reconnect: if Excel or DASYLab is busy or closed, SensorVue-Pro retries on its own and can send the rows it missed
  • CJC, reference and ID columns per unit when you want the full instrument record

Live data

Excel
A new row per interval, or one live row that updates in place
DASYLab
One line per interval into a DDE Input module
DASYLab variables
Each channel to a global variable
Number format
Decimal point or decimal comma
Reconnect
Retry interval of your choice
Missed rows
Sent on reconnect, or skipped for live use

Excel and DASYLab must run on the same PC as SensorVue-Pro.

Pro in practice

Example: 32-point oven survey

A temperature uniformity survey needs many thermocouples logged on the same clock. Four iNet-650s on one PC give 32 type J points, and SensorVue-Pro records them as one table while showing every point live.

UnitConnectionMeasuresGoes to
U1iNet-650 on USB8 points, top shelfCombined log, chart
U2iNet-650 on USB8 points, middle shelfCombined log, chart
U3iNet-650 on USB8 points, bottom shelfCombined log, chart
U4iNet-650 on USBAir, door and load pointsCombined log, digital meters
All units—One row per intervalExcel live sheet for the report

Point locations, intervals and file layout are set up for each job. We can supply the setup file ready to run.

Where it is used

  • Oven and furnace temperature surveys
  • Test stands and product burn-in
  • Ovens, dryers and thermal processes
  • Cold storage and refrigeration
  • HVAC coil and heat exchanger testing
  • Laboratory temperature logging

From sensors to log

  1. Connect thermocouples to each iNet-650 and plug the units into the PC.
  2. Add units on the Units tab and pick each one by serial number.
  3. Set up channels: label, units and scaling.
  4. Choose logging: combined file, per-unit files, Excel or DASYLab.
  5. Save the setup and start logging.

Related solutions

Precision Industrial Sensor IO (iNet-650)

24-bit, 8 differential channels and 4 digital I/O lines, DIN rail mount.

Learn more →

DASYLab data acquisition software

Graphical worksheets for acquisition, analysis, display and control.

Learn more →

Multi-Channel Distributed Temperature Measurement

Many sensors, ROI-IOM nodes and one RS-485 cable to a PC or PLC.

Learn more →

Want SensorVue-Pro set up for your system?

Tell us how many points you need, where they are and how you want the data recorded. We will deliver the iNet-650 units and a SensorVue-Pro setup ready to run, or standard SensorVue if one unit is enough.

Request a quote
Scroll to Top