Modbus RS485 Temperature Monitoring

$1,995.00

Modbus RS-485 temperature monitoring – thermocouples, RTDs and thermistors through our 4-20 mA transmitters into ROI-IOM modules: four sensors per module, many modules on one RS-485 cable to a PLC, SCADA system or PC. Supplied as a configured, tested system.

Request a quote · ROI-IOM specifications →

Out of stock

SKU: ROI-IOM-T485 Category:
ROI-IOM system · Modbus RS-485 · temperature

Temperature sensors on one Modbus RS-485 cable

A Robert Owen Modbus RS-485 temperature monitoring system reads thermocouples, RTDs and 10K thermistors through our 4-20 mA transmitters into ROI-IOM I/O modules. Four sensors per module, many modules on one RS-485 cable, read by a PLC, SCADA system or PC as Modbus RTU registers already scaled to temperature.

ROI-IOM module for Modbus RS485 temperature monitoring of thermocouples, RTDs and thermistors

Which temperature sensors

Signal How it connects Connects to
Thermocouple Through a Robert Owen transmitter to 4-20 mA —
RTD (PT100 / PT1000) Through an ROI-XMA RTD transmitter RTD transmitters
10K NTC thermistor Through an ROI-XMA thermistor transmitter Thermistor transmitters
Existing 4-20 mA temperature transmitter Directly into an ROI-IOM input ROI-IOM

What the system includes

  • ROI-IOM modules, one per four sensors – configured and tested
  • 4-20 mA temperature transmitters matched to your sensors and range
  • Modbus address, baud rate and RTU/ASCII set for your network
  • Software or PLC/SCADA setup as part of the system

Not included unless quoted: sensors, 24 V DC supply, RS-485 cable, PC or PLC.

Why Modbus with the ROI-IOM

  • One cable – many modules share one RS-485 pair, over long distances
  • Any Modbus master – a PLC, SCADA system or PC reads the registers
  • Alarms built in – four relay outputs per module for high/low temperature
  • Scales – from four sensors to hundreds

Supplied as a working system

The ROI-IOM runs our own Modbus RTU/ASCII firmware and ships configured and tested with the rest of your system – one quote for the working result, from one module to hundreds of points.

ROI-IOM specifications →

Common questions

Can the ROI-IOM read a thermocouple directly?

No. Thermocouples, RTDs and thermistors connect through Robert Owen transmitters into the module’s 4-20 mA inputs, which also gives a live zero that shows a broken sensor loop.

How many sensors per module?

Four. Add modules on the same RS-485 cable for more points.

What reads the data?

Any Modbus RTU or ASCII master: a PLC, a SCADA system or PC software. We set up the software or PLC/SCADA side as part of the system.

Can I buy the module on its own?

No. The ROI-IOM is supplied as part of a configured and tested system. Spares and expansion for existing systems are on quote.

Ready to size your system?

Tell us the sensors, how many, the temperature range and what reads the data.

Questions? Contact us – we look forward to answering them.