Modbus RS485 Contact Monitoring

$1,995.00

Modbus RS-485 contact monitoring – dry contacts, 24 V logic and TTL status signals into ROI-IOM modules: up to six inputs and four relay outputs per module, many modules on one RS-485 cable to a PLC, SCADA system or PC. Supplied as a configured, tested system.

Request a quote · ROI-IOM specifications →

Out of stock

SKU: ROI-IOM-C485 Category: Tag:
ROI-IOM system · Modbus RS-485 · contacts

Switch contacts and status signals on one Modbus RS-485 cable

A Robert Owen Modbus RS-485 contact monitoring system reads dry contacts, 24 V logic and TTL-level status signals into ROI-IOM I/O modules – up to six digital inputs per module, many modules on one RS-485 cable to a PLC, SCADA system or PC. Each module also has four relay outputs for alarms and control.

ROI-IOM module for Modbus RS485 contact monitoring with digital inputs and relay outputs

Which signals

Signal How it connects More
Dry contact (switch, relay, float, door) Wetted from the module’s auxiliary supply output —
24 V DC logic Inputs accept 0-40 V —
TTL / 5 V logic Two inputs configurable as 5 V digital I/O —
Alarm or control output Four relay outputs per module, 6 A at 250 V AC ROI-IOM specifications

What the system includes

  • ROI-IOM modules – configured and tested
  • Inputs set for your contact type and voltage
  • Modbus address, baud rate and RTU/ASCII set for your network
  • Software or PLC/SCADA setup as part of the system

Not included unless quoted: contacts and sensors, 24 V DC supply, RS-485 cable, PC or PLC.

Why Modbus with the ROI-IOM

  • Status at a glance – pumps, doors, levels and alarms read as Modbus registers
  • Act on it – relay outputs switch beacons, horns or interlocks
  • Mix with analog – 4-20 mA sensors on the same modules and cable
  • Scales – from a few contacts to hundreds

Supplied as a working system

The ROI-IOM runs our own Modbus RTU/ASCII firmware and ships configured and tested with the rest of your system – one quote for the working result, from one module to hundreds of points.

ROI-IOM specifications →

Common questions

How many contacts per module?

Up to six digital inputs per ROI-IOM module. Add modules on the same RS-485 cable for more.

Do dry contacts need a separate supply?

No. The contacts are wetted from the module’s auxiliary supply output.

What reads the data?

Any Modbus RTU or ASCII master: a PLC, a SCADA system or PC software. We set up the software or PLC/SCADA side as part of the system.

Can I buy the module on its own?

No. The ROI-IOM is supplied as part of a configured and tested system. Spares and expansion for existing systems are on quote.

Ready to size your system?

Tell us the contacts, how many and what should happen when one changes.

Questions? Contact us – we look forward to answering them.