Modbus USB Contact Monitoring

$1,995.00

Modbus USB contact monitoring – dry contacts, 24 V logic and TTL status signals into ROI-IOM modules, up to six inputs and four relays per module, connected to a PC USB port through one USB to RS-485 adapter. Supplied as a configured, tested system.

Request a quote · ROI-IOM specifications →

Out of stock

SKU: ROI-IOM-CUSB Category: Tag:
ROI-IOM system · Modbus over USB · contacts

Switch contacts and status signals to a PC through one USB port

A Robert Owen Modbus USB contact monitoring system reads dry contacts, 24 V logic and TTL-level status signals into ROI-IOM I/O modules – up to six digital inputs per module. The modules share one RS-485 cable that plugs into a PC USB port through a USB to RS-485 adapter, and each module adds four relay outputs for alarms.

ROI-IOM module for Modbus USB contact monitoring through a USB to RS-485 adapter

Which signals

Signal How it connects More
Dry contact (switch, relay, float, door) Wetted from the module’s auxiliary supply output —
24 V DC logic Inputs accept 0-40 V —
TTL / 5 V logic Two inputs configurable as 5 V digital I/O —
Alarm or control output Four relay outputs per module, 6 A at 250 V AC ROI-IOM specifications

What the system includes

  • ROI-IOM modules – configured and tested
  • USB to RS-485 adapter
  • Inputs set for your contact type and voltage
  • PC software set up for your channels

Not included unless quoted: contacts and sensors, 24 V DC supply, RS-485 cable, PC.

Why Modbus with the ROI-IOM

  • One USB port – the whole RS-485 network enters the PC through one adapter
  • Record every change – status changes logged with time on the PC
  • Act on it – relay outputs switch beacons, horns or interlocks
  • Mix with analog – 4-20 mA sensors on the same modules

Supplied as a working system

The ROI-IOM runs our own Modbus RTU/ASCII firmware and ships configured and tested with the rest of your system – one quote for the working result, from one module to hundreds of points.

ROI-IOM specifications →

Common questions

How does a Modbus system connect to USB?

The ROI-IOM modules share one RS-485 cable, and a USB to RS-485 adapter connects that cable to a PC USB port. The PC reads each module as a Modbus device.

How many contacts per module?

Up to six digital inputs per ROI-IOM module. Add modules on the same cable for more.

Do dry contacts need a separate supply?

No. The contacts are wetted from the module’s auxiliary supply output.

Can I buy the module on its own?

No. The ROI-IOM is supplied as part of a configured and tested system. Spares and expansion for existing systems are on quote.

Ready to size your system?

Tell us the contacts, how many and what the PC should do when one changes.

Questions? Contact us – we look forward to answering them.

Like us on Facebook  |  Follow us on X

Scroll to Top