10K NTC TRANSMITTERS

10K NTC THERMISTOR TRANSMITTERS

READ TEMPERATURE SENSORS WITH YOUR PLC

Do you have a PLC and need to read temperature? Did you know, you can use spare PLC 4-20mA inputs for temperature sensor measurement? You can add temperature measurement to a PLC with ROI-XMA sensor transmitters. ROI-XMA thermistor transmitters allow the simple measurement of industry standard 10K NTC thermistor. You can easily use thermistor temperature sensors  to read temperature with you PLC systems.

10K NTC thermistor temperature transmitter
10K NTC thermistor temperature transmitter

4-20mA Thermistor transmitter

10K NTC TRANSMITTERS

Thermistor 4-20mA transmitters are simple to use

Thermistor 4-20mA transmitters are a simple way to add temperature measurement to a PLC. Most installers appreciate how thermistors don’t require you to use special cabling to connect them like RTDs or thermocouples. All you need is standard 2 wire instrumentation cable for both the sensor and transmitter.

4-20mA transmitters can be connected long distances

You can connect 4-20mA transmitters can be over long distances to the PLC. When you use a  standard 24Vdc power source and a 22Awg cable can connect a 4-20mA transmitter over 1,000 feet away. You could be surprised how rapidly the length of a cable increases, when you try to run it neat and out of the way.

Thermistor 4-20mA transmitters are inexpensive

Thermistors are inexpensive and are not polarity dependent. You can easily connect and replace them if damaged. A thermistor is a resistive device. You can easily verify it working with a standard ohm meter and the heat change by holding it, which is a great feature.

ROI-10KXMA050C
0-50 Deg C 10K Ohm NTC Thermistor 4-20mA 2 wire loop powered temperature transmitter ROI-XMA
-10-50 Deg C 10K Ohm NTC Thermistor 4-20mA 2 wire loop powered temperature transmitter ROI-XMA
0-75 Deg C 10K Ohm NTC Thermistor 4-20mA 2 wire loop powered temperature transmitter ROI-XMA
-10-75 Deg C 10K Ohm NTC Thermistor 4-20mA 2 wire loop powered temperature transmitter ROI-XMA

Thermistor transmitters

Robert Owen has years of experience in connecting sensors and software together. Because we code custom software solutions, we can get it done. We offer the approach most suited to the project. We can get it done, regardless of size, because we have the pieces to build solutions. For monitoring anywhere from a single sensor to hundreds. Robert Owen can assist with Sensor Signal ConditioningSensor Signal Processing, and Sensor Data Acquisition. Parts in a range of sensor signal connection services we offer.

To learn more Contact Us we look forward to answering your questions.

Like us on Facebook! and Follow us X!

 

Scroll to Top