4-20mA Thermistor

4-20mA Thermistor signal conditioning allows industry standard Thermistors to be directly connected to PLC 4-20mA inputs and industrial IO modules. The 4-20mA Thermistor connection is a standard format in industrial measurement and control systems. The 4-20mA signal allows the Thermistor measurement to be run much further than the resistive connection of the Thermistor itself. 4-20mA signals can be run directly for thousands of feet, when using the correct cable and power supply. Many PLC inputs either standardly or optionally can be configured for 4-20mA, and it is not unusual to find spare inputs in an installation

Simple PLC Thermistor measurement

4-20mA Thermistor Transmitters The Robert Owen Inc. ROI-XMA 4-20mA sensor transmitter allows PLC Thermistor Measurement. With ROI-XMA; you can use 10K NTC thermistors with standard industrial PLC’s and industrial I/O. The ROI-XMA series of loop powered thermistor transmitters. They convert a thermistors temperature related resistance change. Into a standard 4-20mA instrumentation signal. The ROI-10KXMA series […]

Simple PLC Thermistor measurement Read More »

Example 4-20mA thermistor transmitter wiring diagram

Example 4-20mA thermistor transmitter wiring diagram A Simple 4-20mA Transmitter Operation Description The 4-20mA transmitter can be looked at as a temperature controlled variable load. It is in series with the power supply and current measurement shunt resistance. The effect is similar to the transmitter acting like a potentiometer. One that will vary total load

Example 4-20mA thermistor transmitter wiring diagram Read More »

10K NTC TRANSMITTERS

10K NTC THERMISTOR TRANSMITTERS READ TEMPERATURE SENSORS WITH YOUR PLC Do you have a PLC and need to read temperature? Did you know, you can use spare PLC 4-20mA inputs for temperature sensor measurement? You can add temperature measurement to a PLC with ROI-XMA sensor transmitters. ROI-XMA thermistor transmitters allow the simple measurement of industry

10K NTC TRANSMITTERS Read More »

4-20mA SENSOR TRANSMITTERS

4-20mA SENSOR TRANSMITTERS READ SENSORS WITH YOUR PLC Use spare PLC 4-20mA inputs for sensor measurement, with ROI-XMA transmitters. ROI-XMA sensor transmitters allow the simple measurement of industry standard sensors. Existing sensors can be connected to modern control systems. Read Thermistors, RTDs, or Potentiometers with a PLC. ROI-XMA 4-20mA sensor transmitters are a simple way to

4-20mA SENSOR TRANSMITTERS Read More »